Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
Braz. j. otorhinolaryngol. (Impr.) ; 87(3): 338-345, May-Jun. 2021. tab, graf
Article in English | LILACS | ID: biblio-1285684

ABSTRACT

Abstract Introduction Only 5%-15% of thyroid surgical specimens are reported as malignant. Most of the operations are performed due to suspicion of malignancy as a result of fine needle aspiration biopsy but invasiveness, non-diagnostic results and potential repeat biopsies are disadvantages of fine needle aspiration biopsy. Objective The aim of this study was to investigate the effectiveness of simultaneously using both the strain ratio and elasticity score in the differential diagnosis of thyroid nodules, as well as to assess the compatibility of these two methods. Methods A total of 144 nodules were included in the study. The final histopathologic diagnosis was used as the reference standard. The area under the curve sensitivity, specificity, and cut-off values of the strain ratio and elasticity score were determined using receiver operating characteristic curve analysis. The compatibility and comparison of strain ratio and elasticity score were also performed. Results Twenty eight nodules (19.4%) were malignant. The strain ratio and elasticity score results were found to be significantly successful in predicting thyroid malignancy (p < 0.001 for both). Moreover, the area under the curve for the strain ratio and elasticity score were found to be 0.944 and 0.960, respectively. The diagnostic accuracy of the elasticity score was found to be superior to that of the strain ratio, but this difference was not statistically significant (p = 0.456). When the compatibility of the strain ratio and elasticity score was examined, the two evaluations were revealed to be statistically consistent with each other (Kappa = 0.767; p < 0.001). When the strain ratio and the elasticity score were used together, the specificity of capturing the correct diagnosis increased from 84.5% to 93.1%. Conclusion When the strain ratio an elasticity score were used together for the differential diagnosis of thyroid nodules, more accurate results were obtained. Thus, combining both methods may be a promising alternative to fine needle aspiration biopsy in order to prevent unnecessary surgical interventions for suspected thyroid nodules.


Resumo Introdução Apenas 5% a 15% das amostras cirúrgicas de tireoide são relatadas como malignas. A maioria das cirurgias é feita devido à suspeita de lesão maligna como resultado da biópsia por punção aspirativa com agulha fina. Entretanto, invasividade, resultados não diagnósticos e biópsias repetidas são desvantagens desse procedimento. Objetivo Investigar a eficácia do uso simultâneo da razão de compressão e do escore de elasticidade no diagnóstico diferencial de nódulos tireoidianos, bem como avaliar a compatibilidade desses dois métodos. Método Foram incluídos no estudo 144 nódulos. O diagnóstico histopatológico final foi usado como padrão de referência. A área sob a curva sensibilidade, especificidade e valores de corte da razão de compressão e do escore de elasticidade foram determinados com a análise da curva Receiver Operating Characteristic. A compatibilidade e comparação da razão de compressão e do escore de elasticidade também foram feitas. Resultados Eram malignos 28 nódulos (19,4%). Os resultados da razão de compressão e do escore de elasticidade foram significantemente bem-sucedidos em prever a lesão maligna de nódulos da tireoide (p < 0,001 para ambos). Além disso, as áreas sob a curva para a razão de compressão e o escore de elasticidade foram de 0,944 e 0,960, respectivamente. A acurácia diagnóstica escore de elasticidade foi superior à da razão de compressão, mas essa diferença não foi estatisticamente significante (p = 0,456). Quando a compatibilidade da razão de compressão e do escore de elasticidade foi examinada, as duas avaliações mostraram-se estatisticamente consistentes (Kappa = 0,767; p < 0,001). Quando a razão de compressão e o escore de elasticidade foram usados em conjunto, a especificidade de captar o diagnóstico correto aumentou de 84,5% para 93,1%. Conclusão Quando a razão de compressão e o escore de elasticidade foram usados juntos para o diagnóstico diferencial de nódulos tireoidianos, resultados mais precisos foram obtidos. Assim, o uso combinado dos dois métodos pode ser uma opção promissora à biópsia por punção aspirativa com agulha fina e evitar intervenções cirúrgicas desnecessárias para nódulos tireoidianos suspeitos.


Subject(s)
Humans , Thyroid Nodule/surgery , Thyroid Nodule/diagnostic imaging , Elasticity Imaging Techniques , Sensitivity and Specificity , Biopsy, Fine-Needle , Diagnosis, Differential
2.
Braz. j. otorhinolaryngol. (Impr.) ; 85(3): 282-289, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1011624

ABSTRACT

Abstract Introduction: In daily life biological systems are usually exposed to magnetic field forces at different intensities and frequencies, either directly or indirectly. Despite negative results, the therapeutic use of the low dose magnetic field has been found in recent studies. The effect of magnetic field forces on cochlear cells is not clear in the literature. Objective: In our study, we first applied in vivo pulsed magnetic fields to laboratory rats to investigate the effects on cochlea with distortion product otoacoustic emission test followed by histopathological examinations. Methods: Twelve rats were included in this study, separated into two groups as study group and control group. The rats in the study group were exposed to 40 Hz pulsed magnetic field for 1 h/day for 30 days; the hearing of the rats was controlled by otoacoustic emission test. Also, their cochleas were removed and histochemical examination was performed by Caspase-3, Caspase-9, and TUNEL methods. Results: A statistically significant difference was determined (p < 0.05) when the hearing thresholds of the groups obtained by using 5714 Hz and 8000 Hz stimuli were compared by Kruskal-Wallis test. A significant reaction was observed in the study group, especially in the outer ciliated cells during immunohistochemical examinations by using Caspase-3 and Caspase-9 methods. A significantly positive difference was determined in the study group, especially at the outer ciliated cells and the support cells of the corti organ, when compared to the control group (p < 0.05) by the TUNEL method. Conclusion: According to the results of our study, the very low dose magnetic field, which is considered to be used for therapeutic purposes recently, can cause both auditory function defects and histopathologic damage in cochlear cells.


Resumo Introdução: Os sistemas biológicos são geralmente expostos a forças de campo magnético em diferentes intensidades e frequências, direta ou indiretamente, na vida diária. Apesar dos resultados negativos, o uso terapêutico do campo magnético de baixa dose tem sido encontrado em estudos recentes. O efeito das forças do campo magnético sobre as células cocleares não está claro na literatura. Objetivo: Em nosso estudo, aplicamos pela primeira vez campos magnéticos pulsados in vivo em ratos de laboratório para investigar os efeitos na cóclea através do teste de emissão otoacústica por produto de distorção e análises histopatológicas. Método: Doze ratos foram incluídos neste estudo, os quais foram separados em dois grupos, grupo de estudo e grupo controle. Os ratos do grupo de estudo foram expostos a campo magnético pulsado de 40 Hz por 1 hora/dia por 30 dias, e a audição dos ratos foi controlada por testes de emissão otoacústica. Além disso, suas cócleas foram colhidas e o exame histoquímico foi feito pelos métodos caspase-3, caspase-9 e TUNEL. Resultados: Foi determinada uma diferença estatisticamente significante (p < 0,05) quando os limiares auditivos dos grupos obtidos por meio dos estímulos de 5714 Hz e 8000 Hz foram comparados pelo teste de Kruskal-Wallis. Uma reação significante foi observada no grupo de estudo, especialmente nas células ciliadas externas nas análises imuno-histoquímicas, com os métodos caspase-3 e caspase-9. Uma diferença significantemente positiva foi determinada no grupo de estudo, especialmente nas células ciliadas externas e nas células de suporte do órgão de Corti, quando comparadas com o grupo controle (p < 0,05) pelo método TUNEL. Conclusão: De acordo com os resultados do nosso estudo, o campo magnético de dose baixa, que tem sido considerado para uso terapêutico recentemente, pode causar defeitos na função auditiva e danos histopatológicos nas células cocleares.


Subject(s)
Animals , Male , Rats , Cochlea/pathology , Hair Cells, Auditory, Outer/pathology , Electromagnetic Fields/adverse effects , Immunohistochemistry , Rats, Wistar , Otoacoustic Emissions, Spontaneous , Statistics, Nonparametric
SELECTION OF CITATIONS
SEARCH DETAIL